If the temperature in your home due to its orientation or insulation is not stable and varies, and for this reason there is continuous switching on and off of the boiler, thanks to one of the advanced functions of the VESTA THERMOSTAT can set this trigger sensitivity, saving money and taking care of the heating installation of your home.
This setting corresponds to the hysteresis, having a modification range of 0°C / 3°C that is configurable via the advanced settings of the device.
The temperature range you select will determine when the boiler will start working and when it will stop..
For example, if you select a trigger temperature of 21ºC and the hysteresis is 0.5º (default value), the device will activate the boiler when the temperature is 20.5ºC and deactivate it when the temperature is 21.5ºC .
If we change the hysteresis to 1ºC, the trigger temperature would be 20ºC and the boiler deactivation temperature would be 22ºC.