Advanced setup

To access the advanced settings of your VESTA THERMOSTAT you must turn off the device (make sure nothing appears on the screen, if the connection icon appears, press the on.png button once again until nothing appears);and hold down the M and arriba.pngkeys for 6 seconds. 

To navigate through each of the settings press the M button; to adjust the value in each menu use the arrows arrows.png.

Menu Description Adjustment range Default value
01 Calibrate internal sensor -8ºC ~ 8ºC 0ºC
02 Maximum configurable temperature 5ºC ~ 35ºC 35ºC
03 Minimum configurable temperature 5ºC ~ 35ºC 5ºC
05 Antifreeze function 5ºC ~ 15ºC 5ºC
09 Hysteresis 0.5ºC ~ 3ºC 0.5ºC
11 Screen lock

0: disabled

1: enabled

0
12 Open Window Detection (OWD)

0: disabled

1: enabled

0
13 OWD detection time  2 ~ 30mins 15mins
14 OWD temperature drop 2ºC ~ 4ºC 3ºC
15 Time to deactivate OWD 10 ~ 60mins 30mins
17 Factory reset

0: No

1: Yes (then press the on.png button for 5s and wait for it to restart)

0
18 Software version Read-only version  
31 Software sub-version Read-only version  
32 Standby screen brightness adjustment (only when using USB power supply) 0 ~ 100% 40%

To exit advanced settings, press the on.png button or wait approximately 12 seconds without touching any button for it to automatically exit and save the settings.